3.6.2 Moving the ESD Strap
Use the following procedure to move and reattach the ESD strap:
1. Locate the front ESD packet, shown in Figure 3–4. The packet is adhered to a sheet
metal transformer shield plate located left of the drive cavity. The packet contains the
ESD ground strap, which is attached to the transformer shield plate in the top-right
corner.
2. Move the front ESD ground strap from the top hole to the middle hole on the transformer
shield plate. Attach the strap, using the middle hole screw, as shown in Figure 3–4.
Discard the top and bottom screws. These holes are used for installation of the SA7x
enclosure into the left drive position.
Figure 3–4: Relocating the Front ESD Strap
TOP ESD STRAP
MOUNTING HOLE
MIDDLE ESD STRAP
MOUNTING HOLE
ESD
PACKET
CABINET
FRONT
CXO-2791A
3–8 Installing the SA70–CK Kit