4.3 Dual-Host Installation of an SF3xx Storage Array
3. Install one end of the 108-inch DSSI cable (part number BC21Q–09) to the
I/O panel on the system cabinet (see Figure 4–11).
• Connect the DSSI cable from the DSSI port 1 (of the I/O panel) to the
first DSSI connector of the first KFMSA bulkhead connector on the
system I/O panel.
• Connect the DSSI cable from the DSSI port 2 (of the I/O panel) to the
second DSSI connector of the first KFMSA bulkhead connector on the
system I/O panel.
• Connect the DSSI cable from the DSSI port 3 (of the I/O panel) to the
first DSSI connector of the second KFMSA bulkhead connector on the
system I/O panel.
• Connect the DSSI cable from the DSSI port 4 (of the I/O panel) to the
second DSSI connector of the second KFMSA bulkhead connector on
the system I/O panel.
• Connect the DSSI cable from the DSSI port 5 (of the I/O panel) to the
first DSSI connector of the third KFMSA bulkhead connector on the
system I/O panel.
• Connect the DSSI cable from the DSSI port 6 (of the I/O panel) to the
second DSSI connector of the third KFMSA bulkhead connector on the
system I/O panel.
4.3.3 Labeling the Cables (Dual-Host)
This section describes the steps to label correctly the cables for the host
systems, the SF3xx storage array, and its SF7x storage enclosures and
magazine tape subsystems.
At this point, all steps in the previous sections must be complete.
Digital Multivendor Customer Services or trained installing personnel must
perform the steps that follow.
4–18 Installing an SF3xx Storage Array to a VAX 6000 System