5.2 Cabling the SF7x in Storage Array Position
Plug the other end of this cable into the leftmost DSSI connector at the
rear of the SF7x in SF6.
5. For the cable to port 6, route the DSSI cable on the right side. For the
cable to port 12, route the DSSI cable under the cable retainer on the left
side.
6. Plug two 108-inch DSSI cables (part number BC21Q–09) into ports 6 and
12. Tighten the retainer screws on the 108-inch DSSI cables with your
fingers.
Note
The following step assumes that no SF7x storage enclosures are
installed internally in the system cabinet. If there are SF7x storage
enclosures installed in the system cabinet, then one of the KFMSA
modules installed in the system XMI backplane must be connected to
those SF7x storage enclosures. DO NOT USE this KFMSA module or
its DSSI connections to connect the system to the Sx300 storage array.
7. Plug the other end of the 108-inch DSSI cables into the appropriate ports
on the system I/O panel at the rear of the system cabinet. To determine
which of the two DSSI connectors on the system I/O panel to connect to:
a. Locate the DSSI connectors on the system I/O panel labeled
BLUE/WHITE and RED/WHITE.
b. From port 6 on the Sx300 I/O panel, connect the 108-inch DSSI cable to
the right DSSI connector (RED/WHITE) of the first system I/O panel.
c. From port 12 on the Sx300 I/O panel, connect the 108-inch DSSI cable
to the right DSSI connector (RED/WHITE) of the second system I/O
panel.
CAUTION
Do not apply power to the SF7x enclosure at this time.